The Vortex flow meter is perfectly suited for measuring the flow, pressure and temperature of gases and steam. Ideal for use in steam, wet gas and on the outlet of compressors.

Standard Features

  • Flow Range: 1.5 to 300 Nm/sec (5 to 931 ft/sec)
  • Accuracy: ±1.5% reading, ±0.3% full scale
  • Output: Modbus (RS485) and 4-20mA
  • Power Requirement: 18 to 30VDC / 10W@24V

Options

  • Pressure 16 Bar (gas) or 63 bar (steam)
  • Pipe Sizes: DN15 to DN300
Applications

  • Steam
  • Compressed air and gas
  • Compressor outlets
  • Manufacturing, industrial and pharmaceutical use
  •  Temporary or permanent installation
  • Non-explosive environments
SKU: FLV Categories: , Tags: , Brand:

The Vortex flow meter is perfectly suited for measuring flow and consumption of inert gases and steam in both clean or dirty gas environments. With no moving parts, these sensors are both durable and easy to maintain.

The design of this meter allows for precise measurements of most gases and steam no matter how heavily contaminated. With built-in pressure and temperature sensors, all parameters of your gas or steam system are monitored in one unit, saving you install and maintenance costs. The integrated display allows installers to set the flow meter without any additional equipment and for users to read the information in real time right at the meter.

Important

  • Incorrect wiring or installation can give false readings, damage the sensor and void the warranty. If you aren’t sure how to install or wire the sensor, please contact us. Full installation and wiring instructions are available in the User Manual.

Vortex Flow Meter Pack

  • Flow Meter
  • Calibration certificate
  • User Manual
  • 12 month warranty

Vortex Flow Meter Options

  • Pressure: 1.6 MPa (16 bar) or 6.3 MPa (63 bar)
  • Pipe Section: DN15, DN20, DN25, DN32, DN40, DN50, DN65, DN80, DN100, DN125, DN150, DN200, DN250, DN300
  • Medium: Gas or Steam
    • Gas Types: Air, Argon, Carbon Dioxide, Carbon Monoxide, Helium, Hydrogen, Natural Gas, Nitrogen, Nitrous Oxide, Oxygen

Contact us for other pipe section sizes.

Warranty

12 month warranty

Features

  • Style:  Inline – Flange connection
  • Technology: Karman vortex principle (volumetric)
  • IP Rating: IP65
  • Pipe Sizes: DN15 – DN300 provided minimum velocity is maintained
  • Minimum Flow Velocity: 1.5 Nm/s
  • Flow Range: 1.5 to 300 Nm/s (5 to 931 ft/sec)
  • Gas Parameters:
    • Quality: dirty ⁄ wet air and non-corrosive gases
    • Pressure: up to 16 bar (232 psi)
    • Temperature: -40 to +150°C (-40 to +302°F)
  • Steam Parameters:
    • Pressure: up to 63 bar (913 psi)
    • Temperature: -40 to +280°C (-40 to +536°F)
  • Accuracy: +/-1.5% reading, +/-0.3% full scale
  • Power Requirement: 18 to 30VDC / 10W@24VDC
  • Outputs: Modbus RTU and 4 to 20 mA + Pulse outputs
  • Display: 2″ ultra-wide viewing angle LCD touch screen
  • Data Logging: No
  • Bi-directional: No
  • Measure: Flow, gas pressure, and gas temperature
  • Other Features:
    • Integrated pressure and temperature sensor
    • Ultra-high sensitivity dual vortex probe
    • Turndown ratio of 1:53 goes beyond traditional Vortex flowmeters
    • Full digital signal processing for higher precision and better stability
    • No moving parts
    • Full electrical isolation to filter out disturbances
    • Stable signals
    • Vibration resistant
    • All-welded construction for corrosion resistance, high pressure and high temperature resistance
  • Applications:
    • Steam
    • Compressed air and gas 
    • Manufacturing, industrial and pharmaceutical use
    • Temporary or permanent installation
    • Compressor outlets
  • Warranty: 12 months

Downloads

User Manual

Product Flyer – Specifications and Order Codes

Order Codes (SKU)

Use the diagram below to select the features of your flow meter.

In the example below: FLV105001 is a flow meter that can be used in a 16 bar system with DN40 pipes. Gas / Steam is flowing from left to right. It is configured for gas.

FLV Order Codes

Medium

Gas, Steam

Max Pressure

1.6 MPa (16 bar or 232 psi), 6.3 MPa (63 bar or 913 psi)

Pipe OD

DN15, 1/2", DN20, 3/4", DN25, 1", DN32, 1.25", DN40, 1.5", DN50, 2", DN65, 2.5", DN80, 3", DN100, 4", DN125, 5", DN150, 6", DN200, 8", DN250, 10", DN300, 12"

Flow Direction

Left to Right → → →, Right to Left ← ← ←

HS Code

9026.80.80 (Flow Meters)